| Code 1 | Function | Code 2 | Sensing End Connector | Code 3 | Line/Air Duct Length |
|---|---|---|---|---|---|
| N | No Auto-Cleaning | C | Quick Connector | N | 3 m |
| A | Auto-Cleaning (Including standard DC12V air pump, nozzle) |
C | 3 meters+ quick connector | ||
| A24 | Auto-Cleaning (Including DC24V air pump, nozzle) |
F | Cable Head | Value N | Line length |
| Value C | Line length+ quick connector |
| Code 1 | Function |
|---|---|
| N | No Auto-Cleaning |
| A | Auto-Cleanin (Including standard DC12V air pump, nozzle) |
| A24 | Auto-Cleaning (Including DC24V air pump, nozzle) |
| Code 2 | Sensing End Connector | Code 3 | Line/Air Duct Length |
|---|---|---|---|
| C | Quick Connector | N | 3 m |
| C | 3 meters+ quick connector | ||
| F | Cable Head | Value N | Line length |
| Value C | Line length+ quick connector |
| Residual Chlorin Specification | Temperature Specification | ||
|---|---|---|---|
| Measuring Range |
0~ 20 mg/L Slope reading : 70~ 130% |
Temperature Principle | NTC30K |
| Measuring Rang |
-10~120°C (ATC) | ||
| Accuracy | ±5% F.S | Accuracy | ±0.2°C |
| Resolution | 0.01 mg/L | Resolution | 0.1°C |
| Operating Temperature | 0~60 °C | Reproducibility | 0.1°C |
| Other Specification | |||
| Reaction Time | T90 ≤5 S | Link above | 3/4" NPT |
| Link below | M42 | ||
| Communication | RS-485Modbus RTU Web Browser direct reading (192.168.1.80) |
Housing Material |
PP,acid and alkali resistance/ food grade/zero dissolution |
| Electrode Material | Glass | ||
| Dimension | Ø50 x L213.9mm | ||
| Weight | ≤340g | ||
| Safety certification | CE、FCC | Power | Auto-Cleaning : DC12or24V (Optional) No Auto-Cleaning : DC9~36V |
| Power Consumption |
Auto-Cleaning : 6.8W No Auto-Cleaning : 0.8W |
||
| International Protection Marking |
IP68 | ||
| Residual Chlorin Specification | |
|---|---|
| Measuring Range | 0~ 20 mg/L Slope reading : 70~ 130% |
| Accuracy | ±5% F.S |
| Resolution | 0.01 mg/L |
| Operating Temperature | 0~60 °C |
| Reaction Time | T90 ≤5 S |
| Communication | RS-485Modbus RTU Web Browser direct reading (192.168.1.80) |
| Safety certification | CE、FCC |
| Temperature Specification | |
|---|---|
| Temperature Principle |
NTC30K |
| Measuring Rang |
-10~120°C (ATC) |
| Accuracy | ±0.2°C |
| Resolution | 0.1°C |
| Reproducibility | 0.1°C |
| Other Specification | |
| Link above | 3/4" NPT |
| Link below | M42 |
| Housing Material |
PP, acid and alkali resistance/ food grade/zero dissolution |
| Electrode Material |
Glass |
| Dimension | Ø50 x L213.9mm |
| Weight | ≤340g |
| Power | Auto-Cleaning : DC12or24V (Optional) No Auto-Cleaning : 9~36VDC |
| Power Consumption |
Auto-Cleaning : 6.8W No Auto-Cleaning : 0.8W |
| International Protection Marking |
IP68 |